Solution

Energy Audit Equipment That Stays Installed

Two-Minute Deploy. Permanent Option.

Modern energy audit equipment has to deploy fast, run unattended, and produce defensible reports — without shutting down equipment. Titan Audit clamps onto live conductors with split-core CTs, runs for as long as you need (days, weeks, or permanently), and generates branded PDF audit reports from a phone over WiFi.

Energy audit equipment deployed on a DIN rail — Titan Audit by Tech OVN

The Audit Cost Problem

Traditional portable power loggers cost thousands of pounds to buy or hundreds per week to rent. They require trained technicians to install, collect data for a few weeks, then get removed — leaving the facility blind again. Auditors spend more time managing logger logistics than analysing data.

Titan Audit changes the economics. It deploys as fast as a portable logger but stays as long as you need it — days, months, or permanently. At a fraction of the cost, anyone on the facilities team can install it. ESCOs deploy it across multiple sites simultaneously and convert audits into ongoing M&V contracts without buying new hardware.

Compare Titan Audit to portable loggers →

What Titan Audit Solves

Five reasons facility teams and ESCOs choose Titan Audit over traditional portable loggers.

Two-Minute Deployment

Split-core CTs clamp around existing conductors. Voltage leads connect to the load, or simply plug the meter into a wall socket for current-only logging. No shutdown, no electrician.

Defensible Class 0.5S Data

Same metering engine as the Titan base meter. Class 0.5S accuracy per IEC 62053-22 — utility-grade.

PDF Reports From the Phone

The Tech OVN App connects over WiFi and generates branded PDF audit reports on-site: consumption summary, load profile, power factor trend, TOU breakdown, on/off runtime log. No laptop.

Audit → Permanent Monitoring

When the audit ends, leave the meter installed. It connects to the Energy Intelligence Platform for continuous M&V, baseline tracking, and post-retrofit verification — same hardware.

No Cloud Subscription Needed for Audits

The phone app generates audit reports locally from the meter's stored data. The cloud platform is optional — only needed if you want continuous monitoring after the audit ends.

Tech OVN App generated PDF audit report — consumption summary, load profile, power factor trend

Compliance Use Cases

From BEE PAT in India to ASHRAE Level 2/3 in the US and ISO 50001 globally — Titan Audit is built for compliance-driven audit work.

BEE PAT (India)

The Bureau of Energy Efficiency's Perform, Achieve, Trade scheme requires baseline measurement and post-implementation verification for designated consumers. Titan Audit's TOU registers, harmonics analysis, and Class 0.5S accuracy meet PAT requirements without a separate logger.

ASHRAE Level 2 & Level 3

ASHRAE energy audits require sub-metering of major systems (HVAC, lighting, motors, plug loads). Deploy Titan Audit on each system feeder, run for 1–4 weeks, and export load profiles for the audit report.

ISO 50001 Initial Energy Review

The standard requires identifying significant energy uses (SEUs) and establishing energy performance indicators (EnPIs). Titan Audit captures the load data; the platform calculates and tracks the EnPIs.

Retrofit M&V

Baseline before the retrofit, leave the meter installed, verify savings after. Same hardware, no swap-out, no second deployment cost.

Audit-to-Subscription Path

The Titan Audit value chain typically runs:

  1. 1

    Deploy for an audit (1–4 weeks)

  2. 2

    Generate the PDF audit report from the phone app

  3. 3

    Leave installed as a permanent monitor on the same circuit

  4. 4

    Subscribe to the Energy Intelligence Platform for ongoing analytics

ESCOs particularly benefit: the audit hardware doubles as the M&V hardware, the customer never has to buy a second device, and the ongoing subscription becomes recurring revenue.

Tech OVN App audit workflow — clamp, commission, monitor, report from the phone

Frequently Asked Questions

Seven common questions about energy audit equipment, BEE PAT, and ASHRAE compliance.

Two minutes. Clamp the split-core CTs around the conductors, connect voltage leads (or plug the meter into a wall socket), open the Tech OVN App, and you're logging.
No. Split-core CTs clamp around live conductors. There is no need to disconnect the load or call an electrician.
Yes. The Tech OVN App generates PDF reports locally on the phone from the meter's stored data — no cloud connection or subscription needed for audit mode.
Same Class 0.5S metering engine. Titan uses permanent CTs for fixed installation. Titan Audit uses split-core clamp-on CTs for zero-downtime deployment — temporary or permanent.
Yes. Titan Audit's accuracy class, parameter set, harmonics measurement, and TOU registers meet the BEE PAT measurement requirements for designated consumers.
Yes. At a fraction of the cost of portable loggers, Titan Audit can be left on every circuit for continuous monitoring. Connect it to the Energy Intelligence Platform for ongoing M&V and condition monitoring.
Yes. Deploy one Titan Audit per system feeder (HVAC, lighting, motors, plug loads), run for 1–4 weeks per the ASHRAE protocol, and export the load profiles for the audit report.

Ready to Speed Up Your Next Audit?

Talk to our team about Titan Audit for ESCO projects, BEE PAT compliance, or post-retrofit M&V.